542 Appendix A Command Reference
SXCX
Signal-From-Content Aperture Map
Class Format parameter setting - HDMI active video
Description Sets the proper parameters to values necessary to fit CXAR-shaped image content to the
SXAR-shaped aperture of the signal interface timing format.
Upon executing this command, the following actions are performed:
1. The EXAR value is set to the CXAR value (EXAR=CXAR).
2. The EXCX value is set to 0 (EXCX=0).
3. The SXEX value is set to value entered for this command (SXEX=SXCX).
Command syntax SXCX code
code
0 to 131071 (in decimal)
Note: For help in determining the proper mapping code, follow the procedure on page 318
(EXCX command).
Related commands SXEX, EXAR, EXCX, CXAR, SXCX, SXAR
Example
SXCX 264 //Use centered shrink w/black bars top & bottom