Video Test Generator User Guide 239
AVCO
Analog Video COnfiguration
Class Format parameter setting - Analog video signal
Description Sets the mapping of the analog video colors to the video output connections. The AVCO?
query returns the current setting of AVCO.
Command syntax AVCO type
type
0 = RGB - R to R, G to G, B to B (Normal)
1 = RBG - R to R, B to G, G to B
2 = GRB - G to R, R to G, B to B
3 = GBR - G to R, B to G, R to B
4 = BRG - B to R, R to G, G to B
5 = BGR - B to R, G to G, R to B
Query syntax AVCO?
Query response type
Other required
commands
The FMTU command instructs the generator to use the new setting. The ALLU command
updates hardware to the new setting and redraws the test image.
Example
AVCO 5 // Output blue on red chan and red on blue chan
FMTU // Update hardware to current buffer contents