202 Chapter 12 Using Special Sync Output
3. Set the frame pulse pixel width (in the range from 1 pixel to
HTOT
- 1) by entering the
following command:
FSPW 100
4. Set the frame pulse delay (in the range from 0 <=
FSPD
< (
VTOT
-
FSPW
- 1) [default =
0]) by entering the following command:
FSPD 10
5. Save these settings by entering the following command:
ALLU
To configure line sync on the special sync output:
1. Enable the line sync signal by entering the following commands:
FSPG 0
PSPG 0
LSPG 1
ALLU
The value of composite sync
CSPG
does not matter once these are set.
2. Set the line sync pulse polarity by entering the following command:
LSPP 1 // 1 = high (default)
ALLU
To configure composite sync on the special sync output:
1. Enable digital composite sync by entering the following command:
SSST 2 (or 6,11)
Alternatively, you can press the DCS key on the front panel.
2. Enable the composite sync signal by entering the following commands:
FSPG 0
PSPG 0
LSPG 0
CSPG 1
ALLU
3. Set the composite sync pulse polarity by entering the following commands:
CSPP 1 // 1 = high (default)
ALLU
Seitenansicht 211
1 2 ... 207 208 209 210 211 212 213 214 215 216 217 ... 743 744

Kommentare zu diesen Handbüchern

Keine Kommentare

Pridiom Déshumidificateurs manuels d'utilisation

La liste de Pridiom Déshumidificateurs produits contient 1 manuels d'utilisation pour les modèles 1. Tous les guides d'utilisation en format pdf peuvent être téléchargés ou consultés en ligne.

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
PGD1080HCW
Manuel de l'utilisateur    Pridiom PGD1080HCW User manual [en] , 20 pages