SNUM draw sequence Step NUMber
Classification: Custom image primitive
Command Syntax: SNUM <color> <x> <y>
Limits: <color> = available colors
<x> = positive integer number
<y> = positive integer number
Query Syntax: None
Description: Displays the sequence step number to an image when its drawn
as part of a test sequence. The number, along with the word
Step, appears in a small box. Seq. Step uses three (3) parameters.
The first is the color used for the text and box border. The next
two parameters are the X and Y coordinates for the position of
the box.
Other Required Cmds: The displaying of sequence step numbers must be enabled with
the DNUM command and the custom image must have been
loaded as part of a sequence in order for this primitive to be
drawn.
Example: SNUM white 50 50 // Display seq. num.
// in box with top left corner at
// X=50, Y=50