Quantum-data 700 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Generatoren Quantum-data 700 herunter. Quantum Data 700 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 26
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
Model 700, 701 Video Test Generators
Quick Start Guide
Getting Started ........................................................................................................... 2
Computer Interfaces .................................................................................................... 3
User Interface ............................................................................................................. 4
Selecting Formats ....................................................................................................... 5
Selecting Images ........................................................................................................ 6
Gating Outputs ............................................................................................................ 6
Setting Power Save Preferences ................................................................................. 7
Calibrating Generator .................................................................................................. 8
Adjusting Horizontal Scan Frequency ........................................................................ 10
Detecting Formats Supported by a Monitor ............................................................... 11
Using Test Sequences............................................................................................... 12
Using Generator with CS-1 Probe .............................................................................. 14
Testing Audio ............................................................................................................ 14
Testing HDCP Interfaces ........................................................................................... 15
Generating Psuedo Random Noise ............................................................................ 15
Using Video Generator Manager ................................................................................ 16
Creating Video Formats ............................................................................................. 17
Modifying Test Sequence .......................................................................................... 18
Pattern Descriptions .................................................................................................. 19
Updating Firmware .................................................................................................... 23
Specifications ........................................................................................................... 24
Service and Support Contacts .................................................................................. 25
Contents
Seitenansicht 0
1 2 3 4 5 6 ... 25 26

Inhaltsverzeichnis

Seite 1 - Contents

1Model 700, 701 Video Test GeneratorsQuick Start GuideGetting Started ...

Seite 2 - Getting Started

10 Model 700, 701 Quick Start GuideCalibratingLocking Calibration SettingsThe generator uses an internal hardware jumper to enable and disable changes

Seite 3 - Computer Interfaces

11_______Reading_____Monitor EDID_______COMPLETEDetailsShow details of EDIDafter successful readback from displayunder testComplete indicates EDIDdata

Seite 4 - User Interface

12 Model 700, 701 Quick Start GuideTest MenuPress the Test button to select special test operating modes.Using Test SequencesRunning Test Sequence Ma

Seite 5 - Selecting Formats

13Running Test Sequence in Burn-In ModeSelect Test > Burn-In > Run to automatically cycle through the test sequence. When the Burn-In modeis sto

Seite 6 - Selecting Images

14 Model 700, 701 Quick Start GuideUsing Generator with CS-1 ProbeThe Test > CS1 Probe option uses the Quantum Data CS-1 color sensor to measure th

Seite 7 - _Fmts__ ReloadFmts

15Special Tests2. Choose a DVI video format supported by the device.3. Press Test > HDCP > Start to output HDCP encrypted content.The display on

Seite 8

16 Model 700, 701 Quick Start GuideAbout VGMVideo Generator Manager (VGM) is a Windows-based application for creating and editing formats andtest sequ

Seite 9

17Creating Video FormatsEditing Video FormatsYou can use VGM to create your own video formats. You can start with a default format in the VGMformat ed

Seite 10 - Calibrating

18 Model 700, 701 Quick Start GuideModifying Test SequenceEditing the Test SequenceThe generator has a default sequence, which you can edit in VGM. On

Seite 11 - Learn Monitor

19Flat_Wht/(R,G,B)Description - Fills the screen with white, blue (B), green (G) or red (R).Application - Use to test chrominence.GridDecription - Whi

Seite 12 - Using Test Sequences

2 Model 700, 701 Quick Start GuideGetting StartedUsing AC PowerUse only the AC adaptor provided with the generator to avoid operator injury and damage

Seite 13

20 Model 700, 701 Quick Start Guidepresent across the entire screen, in a large portion of the screen, or localized in a very small area.RasterDescrip

Seite 14 - Special Tests

21RegulateDescription - The image has a pair of white outlined boxes which surround a blinking solid white box.Application - Tests for proper high vol

Seite 15

22 Model 700, 701 Quick Start GuideRampDescription - This image provides an active video area starting from full black (+7.5 IRE for NTSC) atone edge

Seite 16 - Using Video Generator Manager

23Updating FirmwareThe generator’s operating system firmware is stored in Flash EPROM, which you can update via theserial port.Firmware updates are av

Seite 17 - Creating Video Formats

24 Model 700, 701 Quick Start GuideSpecificationsVideo FormatsStorage: 132 totalPress Signal Type button to view signal types.Edit method: Windows-bas

Seite 18 - Modifying Test Sequence

25Service and Support ContactsTo contact Technical Support, see http://www.quantumdata.com/contact/support.asp.For factory-authorized service centers,

Seite 19 - Pattern Descriptions

26 Model 700, 701 Quick Start Guide

Seite 20

3Computer InterfacesRS-232 9-Pin D-Sub PlugPin Signal1 No connection2 Data in (Rx)3 Data out (Tx)4 DTR out5 Ground6 No connection7 RTS out8 CTS inExte

Seite 21

4 Model 700, 701 Quick Start GuideUser InterfaceLCD DisplayThe LCD window displays messages and menu options.Function Buttons_ Item_ 1 ______Item_ 5*_

Seite 22

5 Selecting FormatsViewing Formats by Signal TypePress the Signal Type button, and then select asignal type, to list formats based on theselected sign

Seite 23 - Updating Firmware

6 Model 700, 701 Quick Start GuideSelecting ImagesGating OutputsPress the Gating button to gate outputs, and to switch sync types.Note: Color gating w

Seite 24 - Specifications

7Options MenuPress the Options button to set system-level options.Setting Power Save PreferencesPwr Save:OnNTSC_CAL___ CalibrateClr_Fmts__ Reloa

Seite 25 - Declaration of Conformity

8 Model 700, 701 Quick Start GuideCalibratingModel 700 and 701 generators use programmable hardware to set the amplitude calibration factorsfor analog

Seite 26

9CalibratingCalibrating Outputs1. Select Options > Calibrate > Reset to set the generator’scalibration factors to default nominal values.2. Pres

Verwandte Modelle: 701