3M Multimedia Projector MP8620 Disassembly/Reassembly
3M 1999 2-12
3
4
5
2
1
2-3-8. Remove Audio Speakers
To avoid electrical shocks, unplug projector
power cord before performing any maintenance
to electrical components.
To avoid burns to fingers, allow projector lamp
and internal projector components to cool off prior
to lamp removal or disassembly.
Remove the lamp assembly and power supply.
1.
Remove three (3) screws securing cover.
2.
Lift edge of cover toward front of machine first and
then remove.
3.
Disconnect two (2) cable connectors.
4.
Remove four (4) screws (two on each side) from left
and right speaker brackets.
5.
Remove speakers.
6.
Reassemble in reverse order.
!
!
WARNING