Seitenansicht 21
3M Multimedia Projector MP8670/8745/8755/8770 Adjustments
Copyright 2000, 3M IPC. All Rights Reserved. 1-20
2324
22 14
3029
16 28
3117
32 33
1525
27 26
20
12
13
21
11 1918 10
6 4 8
2 1 3
7 5 9
V/6
V/3
V/3
V/6
H/6 H/6H/3 H/3
2324
22 14
3029
16 28
3117
32 33
1525
27 26
20
12
13
21
11 1918 10
6 4 8
2 1 3
7 5 9
V/6
V/3
V/3
V/6
H/6 H/6H/3 H/3
Adjustment Procedure:
1. Use an SVGA (MP8670) or XGA (MP8745) VESA
(60) timing signal to input a 0.35V p-p G primary
color signal (50% Green).
2. Measure the illumination at points No. 2 and No. 3.
The Values should be:
No. 2 = Y2 (lux)
No. 3 = Y3 (lux)
3. Determine which point (No. 2 or No. 3 has the
higher illumination.
4. Adjust the higher to match the lower. For example,
if Y2 > Y3, Adjust No. 2 G to ± 10 of the value of
Y 3.
Y2 = y3 ± 10
This completes the Green color adjustment.
5. Use an SVGA (MP8670) or XGA (MP8745) VESA
(60) timing signal to input a 0.35V p-p white signal.
6. With a Chroma meter (CL-100) measure point 1.
Make note of the value, this is your benchmark for
the rest of the adjustments.
x = x1
y = y1
Notes
x value is adjusted with “R”
y value is adjusted with “B”
Adjust “B” first then “R” for each Value