Quantum Data 700A Betriebsanweisung Seite 122

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 172
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 121
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running the
Motor
Optimization
SMARTCARD
Operation
Onboard
PLC
Advanced
Parameters
Technical
Data
Diagnostics
UL
Information
122 Quantum MP User Guide
www.emersonct.com Issue: A3
Parameter
Range(
)Default()
Type
9.01 Logic function 1 output OFF (0) or On (1) RO Bit NC PT
9.02 Logic function 2 output OFF (0) or On (1) RO Bit NC PT
9.03 Motorized pot output ±100.00% RO Bit NC PT PS
9.04 Logic function 1 source 1 Pr 0.00 to 22.99 Pr 17.06 RW Uni PT US
9.05 Logic function 1 source 1 invert OFF (0) or On (1) ON (1) RW Bit US
9.06 Logic function 1 source 2 Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.07 Logic function 1 source 2 invert OFF (0) or On (1) OFF (0) RW Bit US
9.08 Logic function 1 output invert OFF (0) or On (1) OFF (0) RW Bit US
9.09 Logic function 1 delay ±25.0s 0.1 RW Bi US
9.10 Logic function 1 destination Pr 0.00 to 22.99 Pr 10.32 RW Uni PT US
9.14 Logic function 2 source 1 Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.15 Logic function 2 source 1 invert OFF (0) or On (1) OFF (0) RW Bit US
9.16 Logic function 2 source 2 Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.17 Logic function 2 source 2 invert OFF (0) or On (1) OFF (0) RW Bit US
9.18 Logic function 2 output invert OFF (0) or On (1) OFF (0) RW Bit US
9.19 Logic function 2 delay ±25.0s 0.0 RW Bi US
9.20 Logic function 2 destination Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.21 Motorized pot mode 0 to 3 2 RW Uni US
9.22 Motorized pot bipolar select OFF (0) or On (1) OFF (0) RW Bit US
9.23 Motorized pot rate 0 to 250s 20 RW Uni US
9.24 Motorized pot scale factor 0 to 4.000 1.000 RW Uni US
9.25 Motorized pot destination Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.26 Motorized pot up OFF (0) or On (1) OFF (0) RW Bit NC
9.27 Motorized pot down OFF (0) or On (1) OFF (0) RW Bit NC
9.28 Motorized pot reset OFF (0) or On (1) OFF (0) RW Bit NC
9.29 Binary sum ones input OFF (0) or On (1) OFF (0) RW Bit NC
9.30 Binary sum twos input OFF (0) or On (1) OFF (0) RW Bit NC
9.31 Binary sum fours input OFF (0) or On (1) OFF (0) RW Bit NC
9.32 Binary sum output 0 to 255 RO Uni NC PT
9.33 Binary sum destination Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.34 Binary sum offset 0 to 248 0 RW Uni US
9.35 Up down disable source Pr 0.00 to 22.99 Pr 0.00 RW Uni PT US
9.36 Up down disable invert OFF (0) or On (1) OFF (0) RW Bit US
9.37 Logic block 1 mode 0 to 4 1 RW Uni US
9.38 Logic block 2 mode 0 to 4 0 RW Uni US
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not copied RA Rating dependent PT Protected US User save PS Power down save